[Determination of ginsenoside compound-K by reversed-phase high performance liquid chromatography]
Wei Zhou1, Zhenshi Luo, Pei Zhou
1Department of Biosynthetic Drug, School of Pharmacy, Fudan University, Shanghai 200032, China.
Abstract:
Ginsenoside compound-K content in ginseng is very low, while it is the main intestinal bacterial metabolite and the final absorption style of the major components, such as ginsenosides Rbl and Rb2. The determination of ginsenoside compound-K in the fermentation liquor of ginseng saponins by reversed-phase high performance liquid chromatography was established. The separation was carried out under the following conditions: a Waters Symmetry C18 column (4.6 mm i.d. x 150 mm, 5 microm) was used at 35 degrees C with acetonitrile-water (48:52, v/v) as mobile phase at a flow rate of 1 mL/min. UV detection wavelength was set at 203 nm. The experimental results showed a good linear relationship between the peak area and mass concentration for ginsenoside compound-K within the range of 0.05-0.8 g/L (r = 0.9998). The relative standard deviation of peak area (n = 6) was 2.20%. The lowest detection limit (S/N = 3) was 2.5 mg/L. The average recoveries (n = 3) for the culture broth of ginseng saponins and notoginseng saponins were 98.6% and 99.7%, respectively. The method is rapid, simple, accurate and reproducible and can be utilized for the research and development of ginsenoside compound-K in pharmaceutical industry.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC)
Published on: March 15, 2017
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...