Related Experiment Video
Updated: Jul 14, 2026

Transthoracic Echocardiography in Mice
Published on: May 29, 2010
Doppler-derived ejection intraventricular pressure gradients provide a reliable assessment of left ventricular
Raquel Yotti1, Javier Bermejo, M Mar Desco
1Department of Cardiology, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain.
Background:
Ejection intraventricular pressure gradients are caused by the systolic force developed by the left ventricle (LV). By postprocessing color Doppler M-mode (CDMM) images, we can measure noninvasively the ejection intraventricular pressure difference (EIVPD) between the LV apex and the outflow tract. This study was designed to assess the value of Doppler-derived EIVPDs as noninvasive indices of systolic chamber function.
Methods And Results:
CDMM images and pressure-volume (conductance) signals were simultaneously acquired in 9 minipigs undergoing pharmacological interventions and acute ischemia. Inertial, convective, and total EIVPD curves were calculated from CDMM recordings. Peak EIVPD closely correlated with indices of systolic function based on the pressure-volume relationship: peak elastance (within-animal R=0.98; between-animals R=0.99), preload recruitable stroke work (within-animal R=0.81; between-animals R=0.86), and peak of the first derivative of pressure corrected for end-diastolic volume (within-animal R=0.88; between-animals R=0.91). The correlation of peak inertial EIVPD with these indices was also high (all R>0.75). Load dependence of EIVPDs was studied in another 5 animals in which consecutive beats obtained during load manipulation were analyzed. During caval occlusion (40% EDV reduction), dP/dtmax, ejection fraction, and stroke volume significantly changed, whereas peak EIVPD remained constant. Aortic occlusion (40% peak LV pressure increase) significantly modified dP/dtmax, ejection fraction, and stroke volume; a nearly significant trend toward decreasing peak EIVPD was observed (P=0.06), whereas inertial EIVPD was unchanged (P=0.6). EIVPD beat-to-beat and interobserver variabilities were 2+/-12% and 5+/-11%, respectively.
Conclusions:
Doppler-derived EIVPDs provide quantitative, reproducible, and relatively load-independent indices of global systolic chamber function that correlate closely with currently available reference methods.
Related Concept Videos
Measurement of Blood Pressure
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation I: Introduction
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests

