Related Experiment Video
Updated: Aug 15, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET
L Livieratos1, L Stegger, P M Bloomfield
1PET Cardiology, MRC Clinical Sciences Centre, Imperial College, Hammersmith Hospital, London, UK. Lefteris.Livieratos@gstt.sthames.nhs.uk
Abstract:
High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.
More Related Videos
08:223D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Planar Rigid-Body Motion
Planar motion is typically divided into three distinct categories. The first is rectilinear translation, demonstrated by a subway train that moves along...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...