Related Experiment Video
Updated: Aug 14, 2026

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Off-line direct deposition gas chromatography/surface-enhanced Raman scattering and the ramifications for on-line
David A Heaps1, Peter R Griffiths
1Department of Chemistry, University of Idaho, Moscow, Idaho 83844-2343, USA.
Abstract:
Surface-enhanced Raman spectra (SERS) of molecules separated by gas chromatography (GC) were measured off-line by condensing the analyte on a moving, liquid-nitrogen-cooled ZnSe window on which a 5 nm layer of silver had been formed by physical vapor deposition. After the components that eluted from the chromatograph had been deposited, the substrate was allowed to warm up to room temperature and transferred to the focus of a Raman microspectrometer where the spectrum of each component was measured. Band intensities in the spectrum of 3 ng of caffeine prepared in this way were approximately the same as in the spectrum of bulk caffeine. By making some logical assumptions, it was shown that identifiable GC/SERS spectra of 30 pg of many molecules could be measured over a 300 cm(-1) region in real-time and that if an optimized substrate were used the minimum identifiable quantity could be reduced to 1 pg or less.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...