Related Experiment Video
Updated: Aug 14, 2026

Subject-specific Musculoskeletal Model for Studying Bone Strain During Dynamic Motion
Published on: April 11, 2018
The influence of early loading on bony crest height and stability: a pilot study
Jean-François Brochu1, James D Anderson, George A Zarb
1Department of Prosthodontics, Tawam Hospital, Dental Center, Al Ain, United Arab Emirates. drjfbrochu@prosthodontiste.ca
Purpose:
The aim of this prospective pilot study was to investigate differences in changes in implant stability and crestal bone height between loaded and unloaded dental implants at 4 months after placement.
Materials And Methods:
In the test group, 20 implants were placed in the anterior region of the mandible in 10 patients. They were connected with a Dolder bar within 10 days and placed into function immediately. In the control group, 21 implants were placed in the anterior region of the mandible in a 2-stage procedure in 12 patients. The implants used were TiUnite, with a diameter of 3.75 mm and a minimum length of 10 mm. Resonance frequency analysis was used to measure differences in implant stability, with the implant stability quotient (ISQ) as the unit of measure. An instrument was developed to measure the bone level directly. On a customized abutment, a probe with a stopper measured the distance between the shoulder of the instrument and the bone. Measurements were made on all 4 sides of each implant. Intra- and interexaminer variability showed an agreement that was greater than 99% (kappa > 0.99) for both sets of measurements.
Results:
In the early loading group, the mean change in ISQ was -0.08 +/- 0.77 and the mean bone loss from buccal, mesial, distal, and lingual sites was 0.69 +/- 0.15 mm. In the unloaded group, the mean change in ISQ was 1.33 +/- 1.65 and the mean bone loss from buccal, mesial, distal, and lingual sites was 0.53 +/- 0.18 mm. There was no statistically significant difference across the 2 treatment groups. The changes in bone height at buccal and lingual sites were not statistically different from the changes at mesial and distal sites. When gender was included as a factor, the changes in stability and bone loss were statistically smaller among female patients than among male patients.
Conclusion:
In this preliminary study, early loading did not show an influence on bony crest height and stability in TiUnite implants placed in the anterior mandible during the first 4 months of service.
Related Concept Videos
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Eccentric Axial Loading in a Plane of Symmetry
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Eccentric Loading
Residual Stresses in Bending
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
