Direct evidence for nonadiabatic dynamics in atom+polyatom reactions: crossed-jet laser studies of F+D2O-->DF+OD

Michael Ziemkiewicz1, Michael Wojcik, David J Nesbitt

  • 1Joint Institute for Laboratory Astrophysics (JILA), National Institute of Standards and Technology and Department of Chemistry and Biochemistry, University of Colorado, Boulder, CO 80309-0040, USA.

Related Concept Videos

Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Van der Waals Interactions01:24

Van der Waals Interactions

Atoms and molecules interact with each other through intermolecular forces. These electrostatic forces arise from attractive or repulsive interactions between particles with permanent, partial, or temporary charges. The intermolecular forces between neutral atoms and molecules are ion–dipole, dipole–dipole, and dispersion forces, collectively known as van der Waals forces.Polar molecules have a partial positive charge on one end and a partial negative charge on the other end of the molecule,...
Bond Dissociation Energy and Activation Energy02:13

Bond Dissociation Energy and Activation Energy

Bond energy is the energy required to break a bond homolytically. These values are usually expressed in units of kcal/mol or kJ/mol and are referred to as bond dissociation energies when given for specific bonds or average bond energies when indicated for a given type of bond over many compounds. Firstly, the bond dissociation energy for a single bond is weaker than that of a double bond, which in turn is weaker than that of a triple bond. Secondly, hydrogen forms relatively strong bonds with...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...