Related Experiment Video
Updated: Aug 13, 2026

A 3D Cartographic Description of the Cell by Cryo Soft X-ray Tomography
Published on: March 15, 2021
High-pass-filtered diffraction microtomography by coherent hard x rays for cell imaging: theoretical and numerical
Tetsuya Yuasa1, Hiroshi Sugiyama, Zhong Zhong
1Department of Bio-System Engineering, Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan. yuasa@eat72.yz.yamagata-u.ac.jp
Abstract:
This paper presents theoretical and numerical studies of diffraction tomography using hard x rays, from the viewpoint of imaging and reconstruction methods for cell imaging. The proposed system employs a single-perfect-crystal analyzer in symmetric Laue-case transmission geometry to efficiently detect the higher spatial frequency components of an object's refractive-index distribution, and to effectively suppress interference between the unperturbated wave field and the wave field diffracted by the object. This system features acquisition of a single projection by a single exposure using a simple geometry and aggressive use of diffracted x rays. We present the physical description of the imaging method using the Fourier diffraction theorem derived from the Born approximation. First, we demonstrate that the reconstruction leads to the phase-retrieval problem. We then describe a reconstruction algorithm based on the classical Gerchberg-Saxton-Fienup algorithm. Finally, we show the efficacy of this system by computer simulation. Our simulation demonstrates that the imaging system delineates microstructure 3.5 microm in diameter in a phase object 400 microm in diameter.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Three-Dimensional Microscopy in Microbiology
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

