Related Experiment Video
Updated: Aug 13, 2026

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Determination of cyanide in blood by isotope-dilution gas chromatography-mass spectrometry
Karen E Murphy1, Michele M Schantz, Therese A Butler
1National Institute of Standards and Technology, Gaithersburg, MD 20899, USA. karen.murphy@nist.gov
Background:
Cyanide (CN) is a lethal toxin. Quantification in blood is necessary to indicate exposure from many sources, including food, combustion byproducts, and terrorist activity. We describe an automated procedure based on isotope-dilution gas chromatography-mass spectrometry (ID GC/MS) for the accurate and rapid determination of CN in whole blood.
Methods:
A known amount of isotopically labeled potassium cyanide (K13C15N) was added to 0.5 g of whole blood in a headspace vial. Hydrogen cyanide was generated through the addition of phosphoric acid, and after a 5-min incubation, 0.5 mL of the headspace was injected into the GC/MS at an oven temperature of -15 degrees C. The peak areas from the sample, 1H12C14N+, at m/z 27, and the internal standard, 1H13C15N+, at m/z 29, were measured, and the CN concentration was quantified by ID. The analysis time was 15 min for a single injection.
Results:
We demonstrated method accuracy by measuring the CN content of unfrozen whole blood samples fortified with a known amount of CN. Intermediate precision was demonstrated by periodic analyses over a 14-month span. Relative expanded uncertainties based on a 95% level of confidence with a coverage factor of 2 at CN concentrations of 0.06, 0.6, and 1.5 microg/g were 8.3%, 5.4%, and 5.3%, respectively. The mean deviation from the known value for all concentrations was <4%.
Conclusion:
The automated ID GC/MS method can accurately and rapidly quantify nanogram per gram to microgram per gram concentrations of CN in blood.
More Related Videos
07:38A General Method for Detecting Nitrosamide Formation in the In Vitro Metabolism of Nitrosamines by Cytochrome P450s
Published on: September 25, 2017
08:51Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...