Related Experiment Video
Updated: Aug 9, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Application of a static solid-phase microextraction procedure combined with liquid-liquid extraction to determine
Ze-Yu Yang1, Eddy Y Zeng, Huan Xia
1State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China.
Abstract:
A static solid-phase microextraction (SPME) procedure combined with liquid-liquid extraction (LLE) was used to determine the poly(dimethyl)siloxane (PDMS)-water partition coefficients (K(f)) for selected polychlorinated biphenyl congeners (PCBs), including PCB 1, 15, 28, 47, 101, 153, 180, 202, 206, and 209. The accuracy for the measurements of analyte concentrations in the aqueous phase was ensured with a one-to-one recovery correction strategy employing one 13C-labeled PCB congener as a surrogate standard for each unlabeled PCB counterpart. The effects of coating thickness (7, 30, and 100 microm) and sample volume (130 mL and 2 L) on the K(f) values were examined experimentally and confirmed with paired t-tests. Significant dependence of K(f) values on coating thickness was found for a few heavily chlorinated congeners only, and was tentatively attributed to the use of the inaccurate effective coating volumes and the structural variation with these PDMS coatings. In addition, no significant differences in the log K(f) values of all analytes except for PCB 206 were found between the sample sizes of 130 mL and 2 L for both the 7- and 100-microm coatings. Overall, K(f) values obtained with 2-L sample containers were consistently higher than those reported in the literature, which is attributable to the selection of appropriate equilibrium times for SPME and direct measurements of aqueous analyte concentrations with LLE in the present study.
More Related Videos
10:34Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...