Related Experiment Video
Updated: Aug 9, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Simultaneous enantioseparation and sensitive detection of eight beta-blockers using capillary
1Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, 30302, USA.
Abstract:
The feasibility of using vancomycin chiral stationary phase (CSP) and polar organic eluent is investigated for simultaneous enantioseparation of eight beta-blockers using CEC coupled to ESI mass spectrometric detection (ESI-MS). The internally tapered capillaries were utilized to pack CEC-MS columns. As compared to externally tapered columns, the use of internally tapered columns demonstrated enhanced stability, durability, and reproducibility. A mixture containing methanol/ACN/acetic acid/triethylamine at 70:30:1.6:0.2 v/v/v/v was considered as optimum mobile phase since it provided a good compromise between resolution and analysis time. As expected, sheath liquid and ESI-MS parameters mainly influenced the detection sensitivity. Interestingly, structural information of beta-blockers was available by varying the MS fragmentor voltage using in-house CID in the scan mode. In order to maximize the chiral/achiral resolution, various column-coupling approaches using teicoplanin as complementary CSP to vancomycin were tested. Several changes in the elution order of beta-blockers were observed using multimodal CSPs with some improvement in chiral or achiral resolution. The quantitative aspects of the CEC-MS method were demonstrated using R- and S-talinolol as internal standards. The calibration curves of beta-blockers showed good linearity in the range of 3-600 microM. The enantiomer of beta-blockers at a concentration of 30 nM was detectable. Furthermore, both 0.1 and 1% of the S-enantiomer could be precisely quantified in the presence of 99.9 and 99% of the R-isomer of beta-blocker.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...