On-line hyphenation of flow injection, miniaturized capillary electrophoresis and atomic fluorescence spectrometry
Dong-Dong Wang1, Feng Li, Xiu-Ping Yan
1Key Laboratory of Functional Polymer Materials (Nankai University), Ministry of Education, Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin 300071, China.
Abstract:
A hyphenated technique was developed for high-throughput speciation analysis by on-line coupling of flow injection (FI), miniaturized capillary electrophoresis (CE) and atomic fluorescence spectrometry (AFS). Two interfaces were used to couple all three systems: the first to couple FI and CE and the second to couple miniaturized CE and AFS. The first interface was a modified flow through chamber, connected to the FI valve with a piece of PTFE tube (0.1mm i.d.x 20 cm long). The capillary outlet was coupled to the AFS by using the second concentric "tube-in-tube" interface. Split sampling was achieved in the electrokinetic mode. Inorganic mercury (Hg(II)) and methylmercury (MeHg(I)) were taken as model analytes to demonstrate the performance of the developed hyphenated technique. A volatile species generation (VSG) technique was employed to convert the analytes from the CE effluent into their respective volatile species. Baseline separation of Hg(II) and MeHg(I) was achieved by CE in a 50 microm i.d.x 8 cm long capillary at 3.0 kV within 60s. The precisions (RSD, n=12) were in the range of 0.7-0.9% for migration time, 3.8-4.2% for peak area, and 2.1-3.5% for peak height. The detection limits were 0.1 and 0.2 microgmL(-1) (as Hg) for Hg(II) and MeHg(I) with a sample throughput of 60 samples h(-1). The recoveries of both mercury species in the water samples studied were in the range of 93-106%.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.