Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study
Murali K Sayana1, Benjamin J Davis, Birender Kapoor
1Department of Trauma and Orthopaedic Surgery, Keele University School of Medicine, Staffordshire, England.
Background:
We studied the effect of additional locking screws on fracture strain and stability in tibial intramedullary nailing.
Methods:
We drilled an additional diaphyseal locking hole into 8-mm solid tibial nails 185 mm from the proximal end of the nail, and locked it proximally and distally. An osteotomy was produced 4.5 cm distal to the additional hole, and the construct loaded axially, in flexion, extension, and torsion. The nails were also tested for their fatigue strength.
Results:
With the additional locking screw, strain increased proximally during loading in neutral and flexion. Strain decreased on loading in extension. The extra locking screw decreased strain close to the osteotomy site in all loading positions. A significant reduction in angular motion at the osteotomy site occurred with the addition of the extra locking screw. The nails survived the fatigue test, although the stress increased around the additional locking hole
Conclusions:
Nails with additional locking options, by altering strain and motion at the fracture site, may have the clinical potential to affect fracture healing.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...