Related Experiment Video
Updated: Aug 8, 2026

Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight (MALDI-TOF) Mass Spectrometry
Published on: June 10, 2018
Carbon-13 labeled polymers: an alternative tracer for depth profiling of polymer films and multilayers using
S E Harton1, F A Stevie, Z Zhu
1Department of Materials Science & Engineering, Analytical Instrumentation Facility, North Carolina State University, Raleigh, NC 27695, USA.
Abstract:
13C labeling is introduced as a tracer for depth profiling of polymer films and multilayers using secondary ion mass spectrometry (SIMS). Deuterium substitution has traditionally been used in depth profiling of polymers but can affect the phase behavior of the polymer constituents with reported changes in both bulk-phase behavior and surface and interfacial interactions. SIMS can provide contrast by examining various functional groups, chemical moieties, or isotopic labels. 13C-Labeled PS (13C-PS) and unlabeled PS (12C-PS) and PMMA were synthesized using atom-transfer radical polymerization and assembled in several model thin-film systems. Depth profiles were recorded using a Cameca IMS-6f magnetic sector mass spectrometer using both 6.0-keV impact energy Cs+ and 5.5-keV impact energy O2+ primary ion bombardment with detection of negative and positive secondary ions, respectively. Although complete separation of 12C1H from 13C is achieved using both primary ion species, 6.0-keV Cs+ clearly shows improved detection sensitivity and signal-to-noise ratio for detection of 12C, 12C1H, and 13C secondary ions. The use of Cs+ primary ion bombardment results in somewhat anomalous, nonmonotonic changes in the 12C, 12C1H, and 13C secondary ion yields through the PS/PMMA interface; however, it is shown that this behavior is not due to sample charging. Through normalization of the 13C secondary ion yield to the total C (12C + 13C) ion yield, the observed effects through the PS/PMMA interface can be greatly minimized, thereby significantly improving analysis of polymer films and multilayers using SIMS. Mass spectra of 13C-PS and 12C-PS were also analyzed using a PHI TRIFT I time-of-flight mass spectrometer, with 15-keV Ga+ primary ion bombardment and detection of positive secondary ions. The (12)C7(1)H7 ion fragment and its 13C-enriched analogues have significant secondary ion yields with negligible mass interferences, providing an early indication of the potential for future use of this technique for cluster probe depth profiling of high molecular weight 13C-labeled fragments.
More Related Videos
06:16MALDI-ToF MS Method for the Characterization of Synthetic Polymers with Varying Dispersity and End Groups
Published on: October 3, 2025
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
MALDI-TOF Mass Spectrometry
Carbon-13 (¹³C) NMR: Overview
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
Determination of Molar Masses of Polymers II
Mass Spectrometry: Isotope Effect