Related Experiment Video
Updated: Aug 8, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Biomechanical responses of human temporomandibular joint disc under tension and compression
1School of Stomatology, Lanzhou University, Lanzhou, 730000, PR China. qishening@hotmail.com
Abstract:
The purpose of this study was to observe the microscopic changes in the temporomandibular joint (TMJ) disc in response to tension and compression, and to study the mechanism of disc failure when subjected to mechanical stresses. The scanning electron microscope was used to observe topographic characteristics of TMJ disc samples obtained from 13 cadavers before and during biomechanical experiments. The stress relaxation experiments were conducted at different strain levels (2, 3, 4 and 6%). The uniaxial tensile experiments were carried out at a constant strain rate (0.05 mm/s). The confined compression tests were performed with 3 different indenters (2, 3 and 4mm in diameter) for 150 s and 3 h. The maximal tensile strain of the disc was 5% (nearly equal to 0.22 MPa of tensile stress) in the mediolaterally tensile direction. Typical wavelike structure of the collagen fibrils of the disc was present at 2-4% strain ranges. Tensile and shear damage to local collagen fibrils was observed in specimens of the intermediate zone and the posterior band at 6% strain level. Changes in the collagen network from a wavelike structure to distortion observed on the surface of the testing samples were reversible in the 150-s indentation, but severe, irreversible breakdown and deformation of the collagen-proteoglycan network occurred in those specimens that had been compressed for 3h. Persistent and prolonged compression inevitably resulted in irrecoverable disc failure. Mechanical stress is a crucial factor in breakdown of the TMJ disc.
Related Concept Videos
Method of Joints: Problem Solving I
Normal Strain under Axial Loading
Tension Response at Adherens Junctions
α-Catenin as a Mechanosensory Protein
The α-catenin of adherens junctions is an allosteric protein with three VH (vinculin homology) domains...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Degenerative Disc Disease ll: Pathophysiology
Applications of Stress
The...