Stopped-Flow Apparatus for X-ray Scattering and XAFS
Journal of Synchrotron Radiation
|October 1, 1994
Summary
A new stopped-flow apparatus enables X-ray scattering and absorption studies on viscous biological solutions at temperatures as low as 253 K. This versatile instrument is ideal for investigating rapid biological reactions.
Area of Science:
- Biophysics
- Biochemistry
- Structural Biology
Background:
- Investigating rapid biological reactions requires specialized equipment capable of handling diverse sample conditions.
- Traditional methods may face limitations with highly viscous solutions or extreme temperatures.
Purpose of the Study:
- To describe a novel stopped-flow apparatus designed for X-ray scattering and X-ray absorption spectroscopy.
- To highlight the apparatus's capabilities in handling viscous solutions and wide temperature ranges.
Main Methods:
- Development and characterization of a stopped-flow apparatus.
- Utilizing X-ray scattering and X-ray absorption techniques.
- Operation across a temperature range down to 253 K with solutions up to 20 cP.
Main Results:
- The stopped-flow apparatus demonstrates successful operation at low temperatures (253 K) with highly viscous solutions (20 cP).
- The instrument is suitable for time-resolved X-ray studies.
Conclusions:
- The described stopped-flow apparatus is a valuable tool for studying the kinetics and mechanisms of biological reactions.
- Its ability to handle challenging sample conditions expands the scope of X-ray studies in biological sciences.
Related Concept Videos
Atomic Fluorescence Spectroscopy
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...
Atomic Absorption Spectroscopy: Instrumentation
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Absorption Spectroscopy: Radiation and Light Sources
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...