Related Experiment Video
Updated: Aug 8, 2026

2-Methacryloyloxyethyl Phosphorylcholine Polymer Treatment of Complete Dentures to Inhibit Denture Plaque Deposition
Published on: December 26, 2016
Effectiveness of microwave irradiation on the disinfection of complete dentures
Mariana Montenegro Silva1, Carlos Eduardo Vergani, Eunice Teresinha Giampaolo
1Department of Dental Materials and Prosthodontics, Araraquara Dental School, São Paulo State University, Brazil.
Purpose:
The purpose of this study was to evaluate the effectiveness of microwave irradiation on the disinfection of simulated complete dentures.
Materials And Methods:
Eighty dentures were fabricated in a standardized procedure and subjected to ethylene oxide sterilization. The dentures were individually inoculated (10(7) cfu/mL) with tryptic soy broth (TSB) media containing one of the tested microorganisms (Candida albicans, Streptoccus aureus, Bacillus subtilis, and Pseudomonas aeruginosa). After 48 hours of incubation at 37 degrees C, 40 dentures were individually immersed in 200 mL of water and submitted to microwave irradiation at 650 W for 6 minutes. Forty nonirradiated dentures were used as positive controls. Replicate aliquots (25 microL) of suspensions were plated at dilutions of 10(-3) to 10(-6) on plates of selective media appropriate for each organism. All plates were incubated at 37 degrees C for 48 hours. TSB beakers with the microwaved dentures were incubated at 37 degrees C for 7 more days. After incubation, the number of colony-forming units was counted and the data were statistically analyzed by Kruskal-Wallis test (alpha = .05).
Results:
No evidence of growth was observed at 48 hours for S. aureus, B. subtilis, and C. albicans. Dentures contaminated with P. aeruginosa showed small growth on 2 plates. After 7 days incubation at 37 degrees C, no growth was visible in the TSB beakers of S. aureus and C. albicans. Turbidity was observed in 3 broth beakers, 2 from P. aeruginosa and 1 from B. subtilis.
Conclusion:
Microwave irradiation for 6 minutes at 650 W produced sterilization of complete dentures contaminated with S. aureus and C. albicans and disinfection of those contaminated with P. aeruginosa and B. subtilis.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Antimicrobial Effectiveness
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...