Related Experiment Video
Updated: Oct 27, 2026

Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Prediction of gas chromatographic relative retention times of stimulants and narcotics
C G Georgakopoulos1, J C Kiburis, P C Jurs
1Doping Control Laboratory, Olympic Athletic Center of Athens, Greece.
Abstract:
The ADAPT software system was used to create models for the prediction of gas chromatographic relative retention times (RRTs) of stimulants and narcotics that are analyzed in doping control of athletes. The two main methods that were followed for building the models were the quantitative structure-retention relationship (QSRR) and multiple linear regression analysis. The main proposed model for the entire data set had a multiple correlation coefficient R = 0.991 and standard error s = 0.046 or approximately 4.5%. Because of the relatively high standard error of the main model, a second model was built on a subset of compounds with R = 0.982 and s = 0.027 or approximately 2.5%.
Related Concept Videos
Drugs Acting on Autonomic Ganglia: Stimulants
Ganglionic stimulants activate NM nicotinic receptors in autonomic ganglia, falling into two categories: nicotine mimetics [e.g., lobeline, dimethylpiperazine, tetramethylammonium] and muscarinic receptor agonists [e.g., muscarine, methacholine]. The first category's action is rapid and blocked by nicotinic receptor antagonists, while the second category's action is delayed and blocked by atropine-like agents. Nicotine, an alkaloid, affects the heart rate by stimulating sympathetic or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
CNS Stimulants: Cocaine, Amphetamines and Cannabinoids

