A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Comparison of camera-based 99mTc-MAG3 and 24-hour creatinine clearances for evaluation of kidney function
Fabio P Esteves1, Raghuveer K Halkar, Muta M Issa
1Department of Radiology, Division of Nuclear Medicine, Emory University School of Medicine, 1364 Clifton Rd. NE, Atlanta, GA 30322, USA.
Objective:
The 24-hour creatinine clearance is the standard clinical technique for measuring kidney function; however, this measurement is cumbersome and inconvenient for patients. We hypothesized that a camera-based technetium-99m mercaptoacetyltriglycine (MAG3) clearance obtained simultaneously with a standard MAG3 scan would correlate well with the 24-hour creatinine clearance and could serve as a simple marker of kidney function.
Materials And Methods:
Data were obtained from a retrospective analysis of 28 patients with varying degrees of kidney dysfunction and 85 subjects evaluated for kidney donation. The MAG3 clearance was calculated using a camera-based technique without blood or urine sampling. The creatinine clearance was measured using the plasma creatinine and a 24-hour urine collection. The MAG3 and creatinine clearances were corrected for body surface area, and clearance values in healthy subjects and patients were compared using the paired Student's t test. The linear association between the MAG3 and creatinine clearances was expressed by Pearson's correlation coefficient.
Results:
The mean MAG3 clearance in the potential kidney donors was 321 +/- 95 mL/min/1.73 m2 (95% CI, 171-546 mL/min/1.73 m2), significantly higher than the mean creatinine clearance of 152 +/- 51 mL/min/1.73 m2 (79-278 mL/min/1.73 m2, p < 0.001). The mean MAG3 clearance in patients was 153 +/- 70 mL/min/1.73 m2 (32-316 mL/min/1.73 m2) and was also significantly higher than the mean creatinine clearance of 74 +/- 36 mL/min/1.73 m2 (21-138 mL/min/1.73 m2, p < 0.001). The ratio of the mean creatinine clearance to the mean MAG3 clearance was essentially the same for volunteers and patients, 0.47 and 0.48, respectively. The Pearson's correlation between the MAG3 and creatinine clearances was 0.80 (0.72-0.86).
Conclusion:
The camera-based 99mTc-MAG3 clearance correlates well with the 24-hour creatinine clearance and can provide a simple and convenient index of kidney function.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...