Related Experiment Video
Updated: Jul 20, 2026

Sampling and Pretreatment of Tooth Enamel Carbonate for Stable Carbon and Oxygen Isotope Analysis
Published on: August 15, 2018
Delta13C analyses of calcium carbonate: Comparison between the GasBench and elemental analyzer techniques
Grzegorz Skrzypek1, Debajyoti Paul
1Department of Earth and Environmental Science, The University of Texas at San Antonio, One UTSA Circle, San Antonio, Texas 78249, USA.
Abstract:
Measurements of stable carbon isotopic composition (delta13C) of carbonates or carbonate-rich soils are seldom performed in a continuous-flow isotope ratio mass spectrometer (IRMS) using an elemental analyzer (EA) as an online sample preparation device. Such analyses are routinely carried out with an external precision better than 0.1 per thousand using a GasBench II (GB) sample preparation device coupled online with a continuous-flow IRMS. In this paper, we report and compare delta13C analyses (86 total analyses) of calcium carbonates obtained by using both the GB and the EA. Using both techniques, the delta13C compositions of two in-house carbonate standards (MERCK carbonate and NR calcite) and ten selected carbonate-rich paleosol samples (of variable CaCO3 content) were analyzed, and data are reported in the VPDB scale calibrated against international standards, NBS 18 and 19. For the in-house standards analyzed by both techniques, a precision better than 0.08 per thousand is achieved. The analytical errors (1sigma) computed from multiple analyses of the delta13C of both the MERCK and NR obtained by the above two techniques are nearly identical. In general, the 1sigma (internal error) of paleosol analyses obtained in the GB is better than 0.06 per thousand, whereas that for the analyses in the EA (three repetitive analyses of the same sample) varies in the range 0.05-0.21 per thousand. However, for paleosols having more than 85% CaCO3, 1sigma is better than 0.15 per thousand (similar to the instrument precision), and in this case the delta13C(VPDB) of samples obtained by the GB is similar to that obtained by the EA. Our results suggest that the delta13C of pure calcium carbonate samples can also be analyzed using the EA technique.
More Related Videos
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Overview
Qualitative Analysis
For instance, group IV...
Carbon-13 (¹³C) NMR: Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...