Estimation of images and nonrigid deformations in gated emission CT
B A Mair1, David R Gilland, Jing Sun
1Department of Mathematics, University of Florida, Gainesville, FL 32611, USA. bam@math.ufl.edu
Abstract:
In this paper, we propose and test a new iterative algorithm to simultaneously estimate the nonrigid motion vector fields and the emission images for a complete cardiac cycle in gated cardiac emission tomography. We model the myocardium as an elastic material whose motion does not generate large amounts of strain. As a result, our method is based on minimizing an objective function consisting of the negative logarithm of a maximum likelihood image reconstruction term, the standard biomechanical model of strain energy, and an image matching term that ensures a measure of agreement of intensities between frames. Simulations are obtained using data for the four-dimensional (4-D) NCAT phantom. The data models realistic noise levels in a typical gated myocardial perfusion SPECT study. We show that our simultaneous algorithm produces images with improved spatial resolution characteristics and noise properties compared with those obtained from postsmoothed 4-D maximum likelihood methods. The simulations also demonstrate improved motion estimates over motion estimation using independently reconstructed images.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
05:07Pulmonary Structural MRI using Free-Breathing, Self-Gated Ultra-short Echo Time Imaging
Published on: September 6, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...