Related Experiment Video
Updated: Jul 19, 2026

Creating Radio-cephalic Arteriovenous Fistula in the Forearm with a Modified No-Touch Technique
Published on: April 1, 2022
Upper extremity arteriovenous fistula does not affect pulse oximetry readings
Rafi Avitsian1, Basem Abdelmalak, Sameh Saad
1Department of General Anaesthesiology, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA. avitsir@ccf.org
Arteriovenous fistula (AVF) creation for hemodialysis alters blood pressure and skin temperature in the upper extremity. However, pulse oximetry (SpO2) readings remain unaffected, provided signal quality is adequate.
Area of Science:
- Vascular Surgery
- Nephrology
- Physiology
Background:
- Arteriovenous fistulas (AVFs) are surgically created in the upper extremity to facilitate hemodialysis.
- Altered blood flow distal to an AVF may theoretically impact physiological measurements.
- Understanding these physiological changes is crucial for patient monitoring and AVF management.
Purpose of the Study:
- To prospectively measure changes in pulse oximetry (SpO2), systemic blood pressure, and skin temperature in the upper extremity of patients with an AVF.
- To compare measurements in the AVF-bearing arm against the contralateral non-AVF arm.
- To identify factors influencing blood flow alterations distal to an AVF.
Main Methods:
- A prospective case-control study design was employed.
- The non-AVF upper extremity served as the control for each patient.
- Evaluated influencing factors included gender, AVF aneurysm, peripheral vascular disease, diabetes mellitus, and vasodilator therapy.
Main Results:
- Thirty patients were enrolled in the study.
- Significant alterations in skin temperature and blood pressure were observed in the hand distal to the AVF.
- No significant changes in SpO2 readings were detected.
Conclusions:
- Upper extremity AVFs significantly alter blood pressure and skin temperature compared to the non-fistula side.
- SpO2 measurements are not significantly affected by the presence of an AVF, assuming adequate signal quality.
- These findings are important for accurate physiological monitoring in patients with AVFs.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pre-Procedural Guidelines for Assessing Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring pulse