Micellar electrokinetic capillary chromatography for fast separation and sensitive determination of melatonin and
Xiaoping Wu1, Weimin Wu, Lan Zhang
1Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Fuzhou University, Department of Chemistry, Fuzhou, P R China.
Abstract:
MEKC was used in conjunction with end-column amperometric detection (AD) at a carbon disc electrode (0.3 mm diameter) for the selective and sensitive determination of melatonin and its five related indoleamines including its precursors and metabolites in the pineal gland. The introduction of a sample stacking technique in injection and the buffer additive SDS in the buffer solution system provided the rapid and sensitive analysis. Optimal buffer conditions (10 mmol/L phosphate containing 20 mmol/L SDS, pH 7.2), detection potential (+1.0 V vs. Ag/AgCl), and electrokinetic injection 10 s with the separation voltage of 24 kV were employed to achieve the baseline separation of six pineal hormones within 15 min. The peak currents and the analyte concentrations have a good linear relationship over the range of 6.0 x 10(-8) 6.0 x 10(-5 )mol/L. The detection limits for six pineal hormones by AD are 9.7 to 41.8 nmol/L (equal to 2.0 to 9.7 ng/mL) (S/N = 3), respectively. It is proved to provide about 30- to 250-fold improvement over UV, and be comparable with the sensitive fluorescence detection, which needs pre-column derivatization. The proposed method has been applied for analysis of melatonin and related indoleamines in rat pineal glands. A very simple sample pretreatment procedure, merely involving the homogenization step in perchloric acid, was enough to achieve recoveries in the range of 71 to 127% for all the analytes in the pineal gland.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
