Related Experiment Video
Updated: Jul 18, 2026

The Use of Thermal Infra-Red Imaging to Detect Delayed Onset Muscle Soreness
Published on: January 22, 2012
Measurement of skin temperature after infrared laser stimulation
M Leandri1, M Saturno, L Spadavecchia
1Interuniversity Centre for Pain Neurophysiology, University of Genova, via Dodecaneso 35, 16146 Genova, Italy.
Objectives:
Several types of lasers are available for eliciting laser evoked responses (LEPs). In order to understand advantages and drawbacks of each one, and to use it properly, it is important that the pattern of skin heating is known and duly considered. This study was aimed at assessing the skin temperature during and immediately after irradiation with pulses by Nd:YAP and CO(2) lasers.
Materials And Methods:
The back of the non-dominant hand was irradiated in 8 subjects. Temperatures were measured by a fast analogical pyrometer (5 ms response time). Stimuli were tested on natural colour (white) and blackened skin.
Results:
Nd:YAP pulses yielded temperatures that were correlated with pulse energy, but not with pulse duration; much higher temperatures were obtained irradiating blackened skin than white skin (ranges 100-194 degrees C vs 35-46 degrees C). Temperature decay was extremely slow in white skin, reaching its basal value in more than 30 s. CO(2) pulses delivered with power of 3W and 6W yielded temperatures of 69-87 degrees C on white skin, and 138-226 degrees C on blackened skin. Temperature decay was very fast (4-8 ms).
Conclusions:
Differences in peak temperatures and decay times between lasers and tested conditions depend on energy and volume of heated skin. The highest temperatures are reached with lesser degree of penetration, as in the case of CO(2) laser and blackened skin. Taking into account the temperature decay time of the skin, the minimum interstimulus interval to get reliable LEPs should be no less than 10 s for Nd:YAP and 100 ms for CO(2) laser. Another important practical consequence of the heating pattern is that the Nd:YAP pulses will activate warmth receptors more easily than CO(2).
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...