Related Experiment Video
Updated: Jul 18, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Digital signal processing for step-scan phase and electrochemical potential double-modulation Fourier transform
Dmitri A Brevnov1, Eliza Hutter, Janos H Fendler
1Center for Micro-Engineered Materials, University of New Mexico, Albuquerque, New Mexico 87131, USA.
Abstract:
Step-scan double-modulation (phase and electrochemical potential) Fourier transform infrared (FT-IR) spectrometry provides both spectroscopic and dynamic information about faradaic reactions. Recently introduced digital signal processing (DSP) can be used, instead of two lock-in amplifiers, for the optical signal demodulation at two modulation frequencies. In order to establish the merits of double-modulation FT-IR spectrometry with DSP, spectro-electrochemical experiments are performed in the attenuated total reflection configuration and with the commonly used ferri/ferrocyanide redox couple. Because of a large potential drop associated with the uncompensated resistance, a satisfactory signal-to-noise ratio for the alternating current (ac) optical measurements is obtained only with the employment of positive feedback compensation. In this arrangement, the amplitude of electrochemical modulation is sufficiently large to convert a significant fraction of the reduced form to the oxidized form and back to the reduced form. Large amplitude ac voltammetry demonstrates that the phase of faradaic admittance at the formal potential is approximately 45 degrees at 2.00 Hz. In addition, these experiments allow for calculation of the interfacial ac potential. This variable is needed for the normalization of the in-phase and the quadrature spectra in order to overcome the problem associated with the iR(u) drop. Because of the integral relationship between the faradaic current and the electromodulation reflectance coefficient, the phases of electromodulation reflectance coefficient with respect to the interfacial ac potential are expected to be -45 degrees and 135 degrees for the reduced and oxidized forms, respectively. However, dynamic information from double-modulation FT-IR spectrometry is available only if demodulation at the electrochemical potential modulation frequency is performed with respect to a defined phase. Because of an undefined demodulation phase implemented in the current version of DSP software, step-scan double-modulation FT-IR spectrometry with DSP is suitable only to provide spectroscopic information. In order to overcome this limitation, the demodulation of the ac optical signal at the electrochemical modulation frequency must be synchronized in phase with the ac potential modulation applied to the electrochemical cell.
More Related Videos
09:46Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging
Published on: April 28, 2022
10:03Proton Transfer and Protein Conformation Dynamics in Photosensitive Proteins by Time-resolved Step-scan Fourier-transform Infrared Spectroscopy
Published on: June 27, 2014
Related Concept Videos
IR Spectrometers
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)