Pulse oximetry during pulmonary artery banding
P A Casthely1, V Redko, J Dluzneski
1Department of Cardiac Anesthesia, a St Joseph's Hospital and Medical Center, Paterson, NJ 07503, USA.
Abstract:
In children with a ventricular septal defect and congestive heart failure, banding of the pulmonary artery (PA) causes equalization of right and left ventricular pressures, reduces the volume of the left-to-right shunt, and diminishes the work of the left ventricle and the engorgement of the pulmonary vessels. However, banding the PA too tightly usually produces hypoxemia by reversing the left-to-right shunt and causes severe hemodynamic changes. A series of 14 infants is reported who underwent PA banding during which a pulse oximeter was used as an early indicator of excessively tight PA banding. Significant hemodynamic changes occurred in eight infants in whom the PA banding was too tight. This consisted of hypotension and bradycardia three to four minutes after the banding. The eight patients also showed significant desaturation of the blood after application of the band, with the arterial hemoglobin saturation (SaO2) dropping from a preband value of 98 +/- 6% to a postband value of 80 +/- 2%. The decrease in SaO2 preceded the hypotension and bradycardia by two to three minutes in all cases. When the band was removed, the hemodynamic and SaO2 changes returned toward baseline. Subsequently, a less tight band was applied; this was associated with a smaller decrease in SaO2, an elevation of blood pressure, and no bradycardia. This was considered to be acceptable banding. The right ventricle/PA pressure gradient significantly decreased after acceptable banding, and a gradient higher than 45 mmHg was usually associated with hypoxemia.
More Related Videos
07:02A Large Animal Model for Pulmonary Hypertension and Right Ventricular Failure: Left Pulmonary Artery Ligation and Progressive Main Pulmonary Artery Banding in Sheep
Published on: July 15, 2021
06:06Oleic Acid-Injection in Pigs As a Model for Acute Respiratory Distress Syndrome
Published on: October 26, 2018
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pulse
The pulse serves as a clinical indicator...