Use of the kinetic plot method to analyze commercial high-temperature liquid chromatography systems. II. Practically
D Clicq1, S Heinisch, J L Rocca
1Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS-TW), Pleinlaan 2, 1050 Brussels, Belgium.
Abstract:
Using a set of experimentally determined plate height data obtained on three commercial high-temperature HPLC supports, and evaluating their isocratic separation speed potential under the application of a set of instrumental constraints, a qualitative map of the practically achievable critical pair separation speed potential of high-temperature HPLC has been established. The obtained data show that the gain in separation speed is more strongly affected by the instrumental limitations in the high-temperature range than it is for the low temperatures. For the presently considered case of alkylbenzene separations, the potential gain in analysis time that can be obtained by going from T=30 to 120 degrees C in the presence of a typical set of instrumental limitations nevertheless remains of the order of a factor of 2-4. The study also shows that improvements on the instrumentation side (increased detector frequency, pumping flow rate, smaller extra-column volumes, ...) are indispensable to fully benefit from the high temperature advantages for all separations requiring less than 10,000 effective theoretical plates.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Types of Detectors
Principles Of Column Chromatography