Related Experiment Video
Updated: Jul 16, 2026

09:43
Protease- and Acid-catalyzed Labeling Workflows Employing 18O-enriched Water
Published on: February 20, 2013
In-source decay causes artifacts in SELDI-TOF MS spectra
Journal of Proteome Research
|March 22, 2007
Summary
Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) can generate additional spectral peaks due to in-source decay. This finding impacts its use for protein biomarker discovery and sequence information.
Area of Science:
- Biochemistry
- Analytical Chemistry
- Proteomics
Background:
- Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) is widely applied in biomarker discovery.
- The technique's spectral output is crucial for identifying potential biomarkers in complex biological samples.
Discussion:
- In-source decay significantly contributes to the generation of additional spectral peaks in SELDI-TOF MS.
- This phenomenon occurs in both pure protein samples and complex serum matrices.
- Understanding in-source decay is vital for accurate data interpretation in SELDI-TOF MS.
Key Insights:
- In-source decay is a key factor influencing SELDI-TOF MS spectra.
- The technique can potentially yield protein sequence information due to in-source decay.
- The findings challenge the uncritical application of SELDI-TOF MS for universal biomarker detection.
Outlook:
- Further research should focus on characterizing and controlling in-source decay for improved SELDI-TOF MS applications.
- Developing refined data analysis methods is necessary to leverage sequence information from in-source decay.
- This study prompts a re-evaluation of SELDI-TOF MS protocols for robust biomarker discovery and validation.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
¹³C NMR: ¹H–¹³C Decoupling
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Tandem Mass Spectrometry
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
MALDI-TOF Mass Spectrometry
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Mass Spectrometry: Molecular Fragmentation Overview
The ionization of a molecule into a molecular ion inside the mass spectrometer causes instability in the molecule's structure due to the loss of an electron. This eventually leads to the fragmentation or breaking of some bonds in the molecule. The fragmentation occurs predominantly at specific bonds to yield relatively stable fragments.
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...

