Investigation of high-speed gas chromatography using synchronized dual-valve injection and resistively heated
Vanessa R Reid1, Adam D McBrady, Robert E Synovec
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA 98195-1700, USA.
Abstract:
High-speed temperature programming is implemented via the direct resistive heating of the separation column (2.3m MXT-5 Silicosteel column with a 180 microm I.D. and a 0.4 microm 5% phenyl/95% dimethyl polysiloxane film). Resistive temperature programming was coupled with synchronized dual-valve injection (with an injection pulse width of 2 ms), producing a complete high-speed gas chromatography (GC) system. A comparison of isothermal and temperature programmed separations of seven n-alkanes (C(6) and C(8)-C(13)) shows a substantial improvement of peak width and peak capacity with temperature programming. The system was further implemented in separations of a mixture of analytes from various chemical classes. Separations of the n-alkane mixture using three different temperature programming rates are reported. A temperature programming rate as high as 240 degrees C/s is demonstrated. The method for determination of temperature programming rate, based on isothermal data, is discussed. The high-speed resistive column heating temperature programming resulted in highly reproducible separations. The highest rate of temperature programming (240 degrees C/s) resulted in retention time and peak width RSD, on average, of 0.5 and 1.4%, respectively, for the n-alkane mixture. This high level of precision was achieved with peak widths-at-half-height ranging from 13 to 36 ms, and retention times ranging from 147 to 444 ms (for n-hexane to n-tridecane).
More Related Videos
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Instrumentation
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.