Fabrication and Characterization of Thickness Mode Piezoelectric Devices for Atomization and Acoustofluidics
Published on: August 5, 2020
A lead-free piezoelectric transformer in radial vibration modes
Mingsen Guo1, D M Lin, K H Lam
1Department of Applied Physics, The Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong, China. gmsone_cm@hotmail.com
Abstract:
In this study, a disk-shaped piezoelectric transformer was fabricated using lead-free (K,Na)NbO(3)-based ceramics with high mechanical quality factor. The transformer can operate in the fundamental or the third radial vibration mode. The transformer is poled along the thickness direction. The top surface is covered by ring/dot silver electrodes separated by an annular gap which serve as the input and output parts of the transformer, respectively. The bottom surface, fully covered with a silver electrode, is grounded as a common electrode. The dimensions of the top ring/dot electrodes are designed such that the third radial vibration mode can be strongly excited. The electrical properties of the transformer with diameter of 34.2 mm and thickness of 1.9 mm were measured. For a temperature rise of 35 degrees C, the transformer has a maximum output power of 12 W. With the matching load, its maximum efficiency is >95%, and maximum voltage gains are 6.5 and 3.9 for the fundamental and the third radial vibration modes, respectively. It has potential to be used in power supply units and other electronic circuits.
More Related Videos
09:51A Polymer-based Piezoelectric Vibration Energy Harvester with a 3D Meshed-Core Structure
Published on: February 20, 2019
07:44Characterization of Full Set Material Constants and Their Temperature Dependence for Piezoelectric Materials Using Resonant Ultrasound Spectroscopy
Published on: April 27, 2016
Related Concept Videos
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Instrument Transformers
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...