Related Experiment Video
Updated: Jul 14, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Monitoring of the smoking process by multicommutation Fourier transform infrared spectroscopy
André F Lavorante1, Salvador Garrigues, Boaventura F Reis
1Department of Analytical Chemistry, Faculty of Chemistry, University of Valencia, Research Building, 50 Dr. Moliner St., 46100 Burjassot, Valencia, Spain.
Abstract:
Nicotine was selected as the target molecule for monitoring of the smoking process by multicommutation Fourier Transform Infrared spectroscopy (FTIR). The method involved the use of CHCl3 for on-line extraction of nicotine from tobacco, cigarette filters and tobacco ash from NH4OH alkalinized samples, and absorbance measurement of the characteristic band at 1316 cm(-1) in the stopped-flow mode, by obtaining the peak area in the range between 1334 and 1300 cm(-1). Under the best operational conditions, the procedure developed provided a detection limit of 0.05 mg mL(-1) nicotine, corresponding to 0.5 mg g(-1) in the solid sample, a relative standard deviation less than 2.5%, and a sampling frequency of 12 determinations h(-1). It can be concluded that nicotine migrates in the smoke mainstream towards the filter during the smoking process. The smoking of cigarettes and cigars is different. Nicotine is retained weakly by both tobacco and filter in the case of cigarettes, and strongly by the unburned tobacco in cigars. The incomplete smoking of cigars and cigarettes reduces nicotine intake and thus reduces the additive effect.
More Related Videos
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
11:05High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
Related Concept Videos
IR Spectrometers
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Gas Chromatography: Types of Detectors-II
IR Frequency Region: Fingerprint Region
The...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...