Related Experiment Video
Updated: Jul 13, 2026

Untargeted Liquid Chromatography-Mass Spectrometry-Based Metabolomics Analysis of Wheat Grain
Published on: March 13, 2020
Broad-spectrum separations in metabolomics using enhanced polar LC stationary phases: a dedicated evaluation using
Ruben t'Kindt1, Goedele Alaerts, Yvan Vander Heyden
1Laboratory of Medical Biochemistry and Clinical Analysis, Ghent University, Ghent, Belgium.
Abstract:
In metabolomics, major efforts are invested in the development of suitable analytical approaches. A tendency towards the use of LC-MS is nowadays very obvious. A great majority of the metabolites of interest are polar to highly polar in nature. We focus on the so-called 'extended polarity' reversed LC phases, developed specifically to allow better retention characteristics for polar compounds. Several of these phases (Atlantis dC18, Inertsil ODS-3, Zorbax XDB, Alltima HP C18) are tested for different column dimension variations (0.5, 1.0, 2.1 mm id) in a specific LC-MS metabolomics setting. Important chromatographic and mass spectrometric quality parameters such as capacity factor, separation efficiency, peak symmetry, sensitivity, and mass accuracy are taken into account. All phases show adequate retention of polar compounds and also perform well with highly aqueous mobile phase compositions. On comparing 1.0 and 2.1 mm id columns, it is clear that the potential gain in sensitivity is not achieved. Using a Lockspray device, accurate mass measurement with a Q-TOF micro is feasible within a mass range of 12 ppm if signal intensities of compound and lockmass are equated. Finally, the extended polarity RP approach in metabolomics experiments is endorsed using real plant extracts.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
11:17A Simple Fractionated Extraction Method for the Comprehensive Analysis of Metabolites, Lipids, and Proteins from a Single Sample
Published on: June 1, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...