CZT detectors: How important is energy resolution for nuclear breast imaging?
Carrie B Hruska1, Michael K O'connor
1Mayo Graduate School, Rochester (MN, USA).
Abstract:
Semiconductor detectors, such as Cadmium Zinc Telluride (CZT), offer improved energy resolution (ER) and potentially improved tumor contrast in breast imaging. We evaluated the effect of changes in ER on tumor contrast. Studies were performed on a prototype CZT detector, a commercial CZT-based system, a multicrystal CsI system and a conventional NaI system. The same low energy high resolution collimator was used on each system and the same total counts (250 kcts) were acquired in each image. CZ-Tmodules in a detector can exhibit different ERs. We imaged a breast phantom containing 4 tumors (diameters 4.9, 7.2, 7.2, and 9.8 mm) over individual CZT modules with intrinsic ers of 5.8-17.5%. Tumor to background ratio was 6.2:1 and tumors were placed 1 and 4 cm deep in the 6-cm thick breast phantom. A standard +/-10% energy window and narrower energy windows (-5%/+10% and -7%/ +10%) were used. Tumor contrast was determined by maximum tumor intensity divided by mean background intensity. Tumor contrast was not significantly affected by differences in ER between CZT modules. Tumor contrast improved by 2-10% with a narrow energy window. At the same ER, the CZT systems yielded slightly better contrast than the CsI system. All pixilated systems performed better than the NaI system. Scatter in the breast was found to be low and accounts for only approximately 11% of counts in a +/-10% energy window for a 6 cm- thick breast. No strong relationship was observed between ER and tumor detectability, which may be due to low scatter in the breast. Detector element size in pixilated systems appears to be more important than ER in determining tumor contrast.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
NMR Spectrometers: Resolution and Error Correction
Mass Analyzers: Overview
Atomic Nuclei: Magnetic Resonance