Related Experiment Video
Updated: Jul 13, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Effect of preload and heart rate on the doppler and tissue doppler-derived myocardial performance index
Kurtuluş Ozdemir1, Sibel Balci, Mehmet Akif Duzenli
1Selcuk University, Meram School of Medicine, Department of Cardiology, Konya, Turkey. kurt33@hotmail.com
Unlabelled:
Doppler-derived myocardial performance index (MPI) has been described as a noninvasive measurement of LV function. Our aim was to investigate the effect of hemodialysis related volume reduction and heart rate changes on the Doppler-derived LV MPI, and Doppler tissue imaging (DTI) derived left and right ventricular MPI.
Method:
The study group comprised 32 consecutive patients (mean age: 43 +/- 18 yrs) undergoing hemodialysis. Patients underwent echocardiography before and immediately after hemodialysis session. Left and right ventricular MPI derived from conventional pulsed-wave Doppler and DTI was calculated. The difference in MPI, heart rate and body weight was calculated before and after hemodialysis.
Results:
Doppler-derived LV MPI, and right ventricular MPI obtained by DTI were increased (p = 0.05) but the LV MPI obtained by DTI was unchanged after hemodialysis. There is a significant positive correlation between the Doppler-derived LV MPI difference and volume reduction (r = 0.38, p = 0.032). The heart rate difference was correlated with Doppler-derived LV MPI difference, and DTI derived right ventricular MPI difference (r = 0.38, p = 0.034; r = 0.48, p = 0.006, respectively). Whereas, DTI derived LV MPI difference was not correlated with heart rate difference. By the multivariate analysis, there was no correlation between Doppler-derived LV MPI difference with heart rate difference, and volume reduction. Right ventricular MPI difference correlated with heart rate difference (r = 0.41, p = 0.021) but not with volume reduction. Doppler-derived MPI is partially influenced by preload and heart rate changes. However, DTI derived LV MPI is not influenced by preload and heart rate changes.
More Related Videos
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Pathophysiology of Cardiac Performance
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...