Related Experiment Video
Updated: Jul 12, 2026

Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
Polymer-coated bismuth film electrodes for the determination of trace metals by sequential-injection analysis/anodic
Georgia Kefala1, Anastasios Economou
1Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki 54124, Greece.
Abstract:
In this work, the utility of polymer-coated bismuth film electrodes (BiFEs) was assessed for the simultaneous on-line determination of Cd(II), Pb(II) and Zn(II) by square-wave anodic stripping voltammetry (SWASV) in the sequential-injection analysis (SIA) mode. The polymeric Nafion coating was initially plated on a glassy carbon electrode forming part of the flow-through electrochemical cell. The subsequent steps of the bismuth layer generation, analyte preconcentration, voltammetric measurement and electrode cleaning were conducted on-line. For a sample volume of 1.2 mL, the limits of detection (at S/N=3) were 2 microg L(-1) for Cd(II) and Pb(II) and 6 microg L(-1) for Zn(II), the coefficients of variation at 20 microg L(-1) were 5.1% for Cd(II), 5.9% for Pb(II) and 6.2% for Zn(II) and the measurement frequency was between 10 and 20 h(-1) (depending on the sample volume aspirated). It is demonstrated that the polymer-coated BiFEs, combined with SIA, can provide an environmentally friendly, sensitive and robust tool to perform rapid and cost-efficient on-line monitoring of trace metals by ASV, even in the presence of surface-active compounds.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Electrodeposition
Electrodeposition can...
Voltammetric Techniques: Linear-Scan (E vs Time)
Electrogravimetric Analysis: Overview
To test the completeness of the...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...