Determination of herbicides by solid phase extraction gas chromatography-mass spectrometry in drinking waters
Related Experiment Video
Updated: Jul 12, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
M C Bruzzoniti1, C Sarzanini, G Costantino
1Department of Analytical Chemistry, University of Torino, Via P. Giuria 5, 10125 Torino, Italy. mariaconcetta.bruzzoniti@unito.it
Abstract:
A solid phase extraction (SPE) method has been optimized for the gas chromatography-mass spectrometry (GC-MS) simultaneous determination of herbicides belonging to the following different families: carbamate (molinate), atrazines (atrazine, propazine, simazine, ametryne, cyanazine, terbutylazine, deethylterbutylazine, deethylatrazine), dinitroaniline (trifluralin, pendimethalin), chloroacetamide (alachlor, metolachlor). Different solid substrates have been compared (C18, cyano, styrene-divinylbenzene, phenyl, graphitic carbon). The type of conditioning and elution solvent, its volume, and the sample flow rate have been considered as variables affecting the recovery yields of the herbicides. The optimized experimental conditions are C18 phase conditioned with 3 mL acetone, loaded with 1L water sample at 5 mL min(-1), and eluted with 3 mL acetone. Good recoveries (included between 79% and 99%) and R.S.D. (included between 2% and 12%) have been obtained for all analytes, except for deethylatrazine whose recovery was 46+/-7%. The recovery of deethylatrazine increases up to 94+/-17% if a non-porous graphitic carbon is coupled to the C18 phase, keeping the other parameters constant as optimized. The optimized method has been successfully checked for the identification and quantitation of the selected herbicides in raw and drinking water samples, with quantitation limits as low as 0.01 microg L(-1), fully in agreement with the current legislation. The method is easily routinable. After development, the method is currently routinely applied for the analysis of herbicides in waters and, up today, more than one thousand samples have been analysed at the "Laboratorio della Società Metropolitana Acque di Torino" (Laboratory of the Municipal Waterworks of Turin) in charge of the control of drinking water quality in Torino.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.

