Related Experiment Video
Updated: Mar 12, 2026

08:23
Analyzing the Photo-oxidation of 2-propanol at Indoor Air Level Concentrations Using Field Asymmetric Ion Mobility Spectrometry
Published on: June 14, 2018
9.3K
Detection of singly ionized oxygen around jupiter
Summary
Forbidden oxygen emission was detected in Jupiter's inner magnetosphere. This finding provides new insights into the planet's plasma characteristics and magnetosphere composition.
Area of Science:
- Planetary Science
- Plasma Physics
- Astrophysics
Background:
- The Jovian magnetosphere is a complex plasma environment.
- Previous studies have focused on sulfur emissions.
Purpose of the Study:
- To detect and characterize forbidden oxygen emission in Jupiter's inner magnetosphere.
- To compare plasma characteristics derived from oxygen and sulfur emissions.
Main Methods:
- Spectroscopic observation of forbidden emission lines.
- Analysis of emission intensity ratios.
Main Results:
- Detection of forbidden oxygen emission at 3726 and 3729 angstroms.
- Emission observed between 4 and 7-8 Jovian radii, concentrated at the magnetic equator.
- Line intensity ratios suggest similar plasma characteristics to those from sulfur emission.
Conclusions:
- Forbidden oxygen emission is a significant component of the inner Jovian magnetosphere.
- Oxygen and sulfur emissions provide consistent information about Jovian plasma.
- This discovery enhances our understanding of Jupiter's magnetospheric processes.
Related Concept Videos
Ionization Energy
44.1K
The amount of energy required to remove the most loosely bound electron from a gaseous atom in its ground state is called its first ionization energy (IE1). The first ionization energy for an element, X, is the energy required to form a cation with 1+ charge:
44.1K
Atomic Emission Spectroscopy: Interference
712
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
712
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
2.1K
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
2.1K
Atomic Emission Spectroscopy: Instrumentation
1.5K
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.5K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
903
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
903
Atomic Absorption Spectroscopy: Interference
2.2K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...