Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Single breath CO measurements normalized to 5% CO2 in Coombs' test positive neonates
1Department of Pediatrics, Hennepin County Medical Center and University of Minnesota, Minneapolis, MN, USA. engel1014@umn.edu
Abstract:
A portable, prototype instrument that measures peak CO, CO2 and H2 concentrations of breath samples was evaluated on 58 antibody positive, blood group incompatible infants. The reproducibility of 108 duplicate breath CO determinations improved when the result was normalized (CO(n)) for the simultaneously measured CO2 concentration (r = 0.97 versus r = 0.87). The average CO(n) for 18 antibody positive, ABO incompatible infants who received phototherapy was 1.2 ppm higher than the average for 32 who did not receive phototherapy (p < 0.001). There was a positive correlation between CO(n) and the duration of phototherapy (r = 0.75). Sodium acetate infusion and breath H2 did not affect the CO(n) results. In antibody positive infants, single breath CO to CO2 ratios provided more reproducible results than CO determinations that were not adjusted for the CO2 concentration. Therefore, a portable instrument that measures both gases on the same aliquot of exhaled air and that is not affected by H2 should have clinical utility as an indicator of heme catabolism and bilirubin production that is not distorted by hyper- or hypoventilation.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...