On-board patient positioning for head-and-neck IMRT: comparing digital tomosynthesis to kilovoltage radiography and cone-beam computed tomography
Related Experiment Video
Updated: Jul 11, 2026

Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Q Jackie Wu1, Devon J Godfrey, Zhiheng Wang
1Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710, USA. jackie.wu@duke.edu
Purpose:
High-precision intensity-modulated radiotherapy demands high patient positioning accuracy. On-board digital tomosynthesis (DTS) provides three-dimensional (3D) image guidance for daily positioning with a lower imaging dose, faster acquisition, and more geometric flexibility than 3D cone-beam computed tomography (CBCT). This clinical study evaluated DTS as a daily imaging technique for patient positioning and compared the results with 3D CBCT and two-dimensional (2D) radiography.
Methods And Materials:
Head and neck cancer patients undergoing intensity-modulated radiotherapy were studied. For each session, the patient was positioned using laser marks. On-board imaging data sets, including 2D kilovoltage radiographs, DTS, and CBCT, were obtained to measure the daily patient positioning variations. The mean and standard deviations of the positioning variations in the translational and rotational directions were calculated. The positioning differences among 2D radiography, DTS, and CBCT were analyzed.
Results:
Image data sets were collected from 65 treatment fractions for 10 patients. The systematic patient positioning variation was <0.10 cm and 1.0 degrees one dimensionally. The random variations were 0.27-0.34 cm in the translational and 0.93 degrees -1.99 degrees in the rotational direction. The mean vector isocenter variation was 0.48 cm. DTS with 40 degrees and 20 degrees scan angles in the coronal or sagittal directions yielded the same results for patient positioning. DTS performance was comparable to that of CBCT, with positioning differences of <0.1 cm and 0.5 degrees . The positioning difference between 2D radiography and DTS was approximately 0.1 cm and 0.2 cm in the vertical/longitudinal and lateral directions.
Conclusion:
Our results have demonstrated that DTS is a comparable 3D imaging technique to CBCT for daily patient positioning of head-and-neck patients as determined by manual registration of bony anatomy.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...