Related Experiment Video
Updated: Jul 11, 2026

Biosensor for Detection of Antibiotic Resistant Staphylococcus Bacteria
Published on: May 8, 2013
Detection of methicillin resistance in Staphylococcus aureus isolated from pediatric patients: is the cefoxitin disk
M J Mimica1, E N Berezin, R L B Carvalho
1Division of Pediatric Infectious Diseases, Department of Pediatrics, Santa Casa University Hospital, Brazil.
Abstract:
We evaluated the performance of several methods for the detection of methicillin resistance in Staphylococcus aureus using 101 clinical S. aureus isolates from pediatric patients in a tertiary hospital in Brazil; 50 isolates were mecA-positive and 51 were mecA-negative. The Etest and oxacillin agar screening plates were 100% sensitive and specific for mecA presence. Oxacillin and cefoxitin disks gave sensitivities of 96 and 92%, respectively, and 98% specificity. Alterations of CLSI cefoxitin breakpoints increased sensitivity to 98%, without decreasing specificity. Our results highlight the importance of a continuing evaluation of the recommended microbiological methods by different laboratories and in different settings. If necessary, laboratories should use a second test before reporting a strain as susceptible, especially when testing strains isolated from invasive or serious infections. With the new (2007) CLSI breakpoints, the cefoxitin-disk test appears to be a good option for the detection of methicillin resistance in S. aureus.
Related Concept Videos
Mechanism of Antibiotic Resistance in MRSA
Clinical Significance of Antibiotic Resistance
Automated Microbial Diagnostics
Antimicrobial Effectiveness
Rapid Identification of Pathogens
Urine Studies II: Urine Culture and Sensitivity Test