SeaWiFS on-orbit gain and detector calibrations: effect on ocean products
Robert E Eplee1, Frederick S Patt, Bryan A Franz
1Science Applications International Corporation, 4600 Powdermill Road, Suite 400, Beltsville, Maryland 20705, USA. Robert.E.Eplee@nasa.gov
Abstract:
The NASA Ocean Biology Processing Group's Calibration and Validation Team has analyzed the mission-long Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) on-orbit gain and detector calibration time series to verify that lunar calibrations, obtained at nonstandard gains and radiance ranges, are valid for Earth data collected at standard gains and typical ocean, cloud, and land radiances. For gain calibrations, a constant voltage injected into the postdetector electronics allows gain ratios to be computed for all four detectors in each band. The on-orbit lunar gain ratio time series show small drifts for the near infrared bands. These drifts are propagated into the ocean color data through the atmospheric correction parameter epsilon, which uses the 765/865 nm band ratio. An anomaly analysis of global mean normalized water-leaving radiances at 510 nm shows a small decrease over the mission, while an analysis of epsilon shows a corresponding increase. The drifts in the lunar time series for the 765 and 865 nm bands were corrected. An analysis of the revised water-leaving radiances at 510 nm shows the drift has been eliminated, while an analysis of epsilon shows a reduced drift. For detector calibrations, solar diffuser observations made by the individual detectors in each band allows the response of the detectors to be monitored separately. The mission-long time series of detector calibration data show that the variations in the response of the individual detectors are less than 0.5% over the mission for all bands except the 865 nm band, where the variations are less than 1%.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Calibration Curves: Correlation Coefficient
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...