Relative blood volume measurements during hemodialysis: comparisons between three noninvasive devices
Judith J Dasselaar1, Roel M Huisman, Paul E DE Jong
1Dialysis Center Groningen, Division of Nephrology, University Medical Center Groningen and University of Groningen, Groningen, The Netherlands.
Abstract:
The monitoring of relative blood volume changes (DeltaRBV) has been advocated for the prevention of hemodialysis (HD) hypotension. Stand-alone devices (Crit-Line) or devices incorporated into the HD apparatus (blood volume monitor [BVM], Hemoscan) are widely used for this purpose. Comparisons between devices are scarce. The aim of this study was, first, to compare DeltaRBV results from these 3 devices with DeltaRBV calculated from changes in laboratory-derived hemoglobin (DeltaRBV-lab-Hb) and, second, to compare DeltaRBV results between the different devices. Fourteen patients received 2 HD treatments in a randomized order: one with the Hemoscan and Crit-Line combination and one with the BVM and Crit-Line combination. DeltaRBV-lab-Hb was measured at 2 and 4 hr into the HD session. Bland-Altman analyses showed that DeltaRBV results from the 3 devices differed systematically from DeltaRBV-lab-Hb, i.e., the difference between the 3 devices and DeltaRBV-lab-Hb varied significantly (p<0.05) with the magnitude of the measurement. The interdevice comparison showed considerable differences in DeltaRBV results. At the end of the treatment, a significant difference (p<0.05) between DeltaRBV measured by the Hemoscan and Crit-Line device (-9.8+/-2.7% and -11.5+/-4%, respectively) was found. In most patients, a systematic difference between Crit-Line and Hemoscan and between Crit-Line and BVM was observed. Relative blood volume change measurements by Crit-Line, Hemoscan, and BVM yield results that differ systematically from the results obtained from laboratory-derived Hb changes. Furthermore, there are substantial differences in DeltaRBV results between the 3 DeltaRBV devices.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hemodialysis I: Introduction
Measurement of Blood Pressure
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Hemodialysis II: Procedure and Complications
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate