Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Torque01:10

Torque

18.5K
Torque is an important quantity for describing the dynamics of a rotating rigid body. We see the application of torque in many ways in the world, such as when pressing the accelerator in a car, which causes the engine to apply additional torque on the drivetrain. Here, we define torque and provide a framework to create an equation to calculate torque for a rigid body with fixed-axis rotation.
Torque can be considered as the rotational counterpart to force. Since forces change the translational...
18.5K
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

5.6K
The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
5.6K
Toroids01:27

Toroids

3.4K
A toroid is a closely wound donut-shaped coil constructed using a single conducting wire. In general, it is assumed that a toriod consists of multiple circular loops perpendicular to its axis.
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb points in the...
3.4K
Torque Free Motion01:15

Torque Free Motion

942
The torque-free motion refers to the movement of a rigid body in space when no external torques are acting upon it. This type of motion can be observed in environments where there are no external forces or frictions, like in outer space. For example, a rotation of Mars in space is a torque-free motion. Mars is an axisymmetric object, meaning it has an axis of symmetry along which it rotates, designated as the z-axis. The rotating frame of reference is defined such that the center of mass of...
942
Torsion of Noncircular Members01:16

Torsion of Noncircular Members

901
Circular shafts undergoing torsional stress maintain their cross-sectional integrity due to their axisymmetric nature. This symmetry ensures an even distribution of stress, allowing the shaft to withstand torsion without distorting. In contrast, square bars, lacking this axial symmetry, experience significant distortion across their cross-sections when subjected to torsion, with the exception of along their diagonals and at lines connecting midpoints. A detailed examination of a cubic element...
901
Thin-Walled Hollow Shafts01:15

Thin-Walled Hollow Shafts

740
In analyzing a thin-walled hollow shaft subjected to torsional loading, a segment with width dx is isolated for examination. Despite its equilibrium state, this segment faces torsional shearing forces at its ends. These forces are quantitatively described by the product of the longitudinal shearing stress on the segment's minor surface and the area of this surface, leading to the concept of shear flow. This shear flow is consistent throughout the structure, indicating a uniform distribution of...
740

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Systematic Evaluation of Data and Trial Fitness for Oncology Trial Emulation: Empirical Findings from the CARE Initiative.

Clinical pharmacology and therapeutics·2026
Same author

Transportation as a Barrier to Health Care Access Among Patients With Knee Arthritis: Cross-Sectional Study.

JMIR formative research·2026
Same author

Assessment of the adequacy of the Fast Healthcare Interoperability Resources (FHIR) Genomics standard for the representation of somatic testing reports.

JAMIA open·2026
Same author

Transportation as a Barrier to Healthcare Access Among Patients with Knee Arthritis: Cross-Sectional Study.

JMIR formative research·2026
Same author

When Our "Best" Isn't Good Enough: Asleep Paralyzed Fiberoptic Intubation After a Failed Awake Fiberoptic at an Outside Hospital.

Cureus·2025
Same author

The Assessment of Practical and Safety Aspects of Recommended Surface Disinfection and Ultraviolet-C Cleaning Procedures for the Anesthesia Workspace.

Cureus·2025
Same journal

Erratum: Bacterial Turbulence at Compressible Fluid Interfaces [Phys. Rev. Lett. 136, 138301 (2026)].

Physical review letters·2026
Same journal

Unveiling Light-Quark Yukawa Flavor Structure via Dihadron Fragmentation at Lepton Colliders.

Physical review letters·2026
Same journal

Adaptable Route to Fast Coherent State Transport via Bang-Bang-Bang Protocols.

Physical review letters·2026
Same journal

Topological Transition and Emergence of Elasticity of Dislocation in Skyrmion Lattice: Beyond Kittel's Magnetic-Polar Analogy.

Physical review letters·2026
Same journal

Pound-Drever-Hall Method for Superconducting-Qubit Readout.

Physical review letters·2026
Same journal

Coupling a ^{73}Ge Nuclear Spin to an Electrostatically Defined Quantum Dot in Silicon.

Physical review letters·2026
See all related articles

Related Experiment Video

Updated: May 1, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
11:00

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section

Published on: July 19, 2016

10.3K

Comment on "torus instability"

James Chen1

  • 1Plasma Physics Division Naval Research Laboratory Washington, D.C. 20375, USA.

Physical Review Letters
|October 13, 2007
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Magnetically Induced Rotating Rayleigh-Taylor Instability
06:42

Magnetically Induced Rotating Rayleigh-Taylor Instability

Published on: March 3, 2017

9.2K
Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel
10:03

Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel

Published on: October 5, 2018

7.5K

Related Experiment Videos

Last Updated: May 1, 2026

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
11:00

Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section

Published on: July 19, 2016

10.3K
Magnetically Induced Rotating Rayleigh-Taylor Instability
06:42

Magnetically Induced Rotating Rayleigh-Taylor Instability

Published on: March 3, 2017

9.2K
Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel
10:03

Uncoupling Coriolis Force and Rotating Buoyancy Effects on Full-Field Heat Transfer Properties of a Rotating Channel

Published on: October 5, 2018

7.5K