Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Calibrated photoplethysmographic estimation of digital pulse volume and arterial compliance
Rein Raamat1, Kersti Jagomägi, Jaak Talts
1Department of Physiology, University of Tartu, Tartu, Estonia. rein.raamat@ut.ee
Abstract:
Digital pulse volume and arterial compliance have been estimated by using the finger arterial pressure and volume waveforms when performing measurements at rest and during local cold exposure in 17 volunteers. The amplitude-based algorithm determines compliance as a ratio of finger volume and pressure pulses. Cooling was conducted by immersion of the contra-lateral arm in water at 11 degrees C for 2 min. Continuous non-invasive finger blood pressure was measured by the Finapres monitor, while the finger volume pulses were recorded by the UT9201 physiograph, which provides a photoplethysmographic registration of volume changes in a large range of transmural pressures (P(transm)). The photoplethysmographic signal was calibrated by applying a graded modulation to the cuff. The study demonstrated that contra-lateral arm cooling induced a statistically significant (P<0.001) reduction in the digital arterial compliance at P(transm) approximately 0 as well as at P(transm) = 50 mmHg. The median compliance diminished during cooling from 0.67 mm(3 )mmHg(-1) to the level of 55% at P(transm) approximately 0, and from 0.14 mm(3 )mmHg(-1) to the level of 42% at P(transm) = 50 mmHg respectively. The observed changes were mostly due to the reduction in the pulse volume. Digital arterial pressure and volume waveforms recorded by the Finapres monitor combined with a calibrated photoplethysmograph can be used in estimating the absolute values of the dynamic compliance of finger arteries. A quantitative estimation instead of the non-calibrated recording of the digital pulse volume allows shortening the variability and widening the scope of finger arterial compliance measurements.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)