Secondary interactions, an unexpected problem emerged between hydroxyl containing analytes and fused silica
A Castillo1, A F Roig-Navarro, O J Pozo
1Research Institute for Pesticides and Water, Universitat Jaume I, E-12071 Castelló, Spain.
Abstract:
Relevant secondary interactions (hydrogen-bond type), additional to the main anion-exchange mechanism, were found when a method for As, Se and Cr speciation was developed based on microLC-inductively coupled plasma mass spectrometry (ICP-MS) coupling. In order to get the claimed analytical performance characteristics of the microbore columns, microLC systems are equipped with very narrow bore fused silica capillaries. When a mobile phase of NH(4)NO(3) at pH 8.7 was used, a notable tailing was observed for As(III), As(V), MMA and Se(IV), species containing hydroxyl groups in its chemical structure at this pH value. However, additional interactions appeared neither when the fused silica capillaries of the capillary LC system were substituted for polyetheretherketone (PEEK) nor operating at pH below 8.5. A mechanism to explain the additional interaction observed is proposed and tested in this work. It seems that high pH values produce a partial hydrolysis of the siloxane groups of the fused silica capillaries. Under these conditions, degradation products of silica, containing ionized silanol groups, reach the column and interact with the anion-exchange resin. Then, ionized silanol groups, retained on the column, can interact with the hydroxyl moiety of the aforementioned analytes leading to severe peak tailing and broadening. Different strategies were evaluated to solve the problem. The addition of a salt containing hydroxyl groups in the mobile phase such as hydrogen phosphate, the diminution of the pH and the use of PEEK capillaries in the microHPLC system demonstrated to be suitable. Finally, two alternative microHPLC-ICP-MS separations, based on a gradient elution of NH(4)NO(3) at pH 8.0 and NH(4)NO(3)/NH(4)H(2)PO(4) at pH 8.7, were optimized and compared. Results showed better peak shapes for some species when hydrogen phosphate was added to the mobile phase.
More Related Videos
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
10:41Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion Exchange
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...