Extraction and Characterization of Surfactants from Atmospheric Aerosols
Published on: April 21, 2017
Capillary electrochromatography-mass spectrometry of nonionic surfactants
1Department of Chemistry, Center of Biotechnology and Drug Design, Georgia State University, Atlanta, Georgia 30303, USA.
Abstract:
The Triton X (TX)-series are alkylphenol polyethoxylates -type nonionic surfactants of varying numbers of ethylene oxide units. Applications include industrial and household detergent formulations as well as emulsifying agents. For analysis of these surfactants, capillary electrochromatography-electrospray ionization-mass spectrometry (CEC-ESI-MS) offers several unique advantages over the traditional hyphenation methods based on HPLC-MS. These include higher plate numbers attainable in CEC-MS, as well as more compatible flow rate (submicroliter) when coupled to ESI-MS and, perhaps most importantly, less consumption of toxic and costly organic solvents. In this work, different CEC-ESI-MS parameters such as mobile-phase composition, sheath liquid, and spray chamber parameters were optimized to provide suitable and sensitive analysis of short-, medium-, and long-chain length (e.g., n = 1-16) TX-series nonionic surfactants. The optimized CEC-ESI-MS conditions were mobile phase containing 90/10 ACN/2.5 mM Tris, pH 8, sheath liquid containing 50/50 MeOH/10 mM HCO(2)NH(4) delivered at 5 microL/min, spray chamber set to drying gas flow of 6 mL/min, nebulizer pressure of 5 psi, and drying gas temperature set to 200 degrees C. This optimization is followed by the more challenging separation of very long chain TX-series with a large number (n = 30-70) of ethoxy units, which were initially found to exhibit extreme retention using the developed method. It was observed that through the addition of small volume fraction of polar-aprotic tetrahydrofuran solvent to the running buffer, the retention time could be significantly reduced thus enhancing the feasibility for CEC-ESI-MS analysis of these very long chain nonionic surfactants for the first time. The detection limit was approximately 37 microg/mL total octylphenol ethoxylate for TX-45; acceptable precision of migration time (<1% RSD, n = 3) and peak area ( approximately 4% RSD, n = 3) were achieved.
More Related Videos
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Surface Active Agents
High-Performance Liquid Chromatography: Types of Detectors