Related Experiment Video
Updated: Jul 10, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Dose coefficients calculated using the new ICRP model for the human alimentary tract
A W Phipps1, T P Fell, J D Harrison
1Radiation Protection Division, Health Protection Agency, Chilton, Didcot, Oxon OX11 0RQ, UK. alan.phipps@hpa.org.uk
Abstract:
Publication 100 of the International Commission on Radiological Protection (ICRP) provides a Human Alimentary Tract Model (HATM) to replace the gastrointestinal (GI) model described in Publication 30. The HATM will be used for future calculations of dose coefficients and bioassay predictions, first in a series of publications on occupational intakes of radionuclides, and subsequently in revision of dose coefficients for public exposures. This paper compares dose coefficients calculated using the new model with current values calculated using the GI model for a range of radionuclides. Colon doses are lower using the HATM in all cases considered, in some cases by significant factors. Stomach doses tend to be lower, but are in some cases higher under HATM. The extent to which these changes in doses to gut tissues impacts upon the effective dose varies among nuclides, but there is a tendency for lower effective doses. Special-case applications of the HATM are also described, considering retention on teeth or in the walls of the small intestine. Although the effect of such retention on the regional tissue dose can be large, the effective dose is not greatly changed.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Dose Size and Dosing Frequency: Determination Methods
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Compartment Models: Single-Compartment Model