Background:
Because of poor patient compliance and clinical inertia, hypertension control rates remain poor. Home blood-pressure measurements (HBPM) improve compliance of patients and achievement of blood pressure (BP) targets. However, few studies have evaluated self-BP management by patients.
Methods:
In a multicenter, prospective, single-group, open-label pilot study of 111 patients whose hypertension was uncontrolled despite monotherapy, we studied satisfaction with, and feasibility of, HBPM and self-titration of antihypertensive treatment using telemedicine for compliance, efficacy, and safety. After education (protocol, action plan, and use of the HBPM device), patients performed a sequence of HBPM every 2 weeks for 8 weeks. Following a stepwise approach, treatment was increased by the patient at weeks 4 and 6 if average HBPM values exceeded predefined limits. For each titration, the patient informed the Core Center by telemedicine, but BP values were transferred automatically.
Results:
Overall, 80% of patients were satisfied (58%) or very satisfied (23%) with the program (95% confidence interval, 73% to 87%). Regarding compliance, 78% of patients fully complied with self-measurement, and just over 71% titrated their treatment adequately. Physicians were satisfied (52%) or very satisfied (22%) with the program. Between the first and final visits (at week 8), office systolic/diastolic BP (mean +/- SD) decreased significantly from 151 +/- 9/91 +/- 6 to 143 +/- 13/84 +/- 11 mmHg. During the trial, HBPM (mean +/- SD) decreased significantly from 149 +/- 13/86 +/- 12 to 138 +/- 16/81 +/- 10 mmHg. No significant safety issues were reported.
Conclusions:
This innovative approach to the management of hypertension, combining self-measurement and self-titration, is feasible, well-accepted by both patients and physicians, and safe.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement