Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
Published on: October 17, 2016
Common-path optical coherence tomography with side-viewing bare fiber probe for endoscopic optical coherence
1Department of Electrical and Computer Engineering, Johns Hopkins University, 3400 N. Charles Street, Baltimore, Maryland 21218, USA.
Researchers developed a miniaturized, side-viewing optical coherence tomography (OCT) probe using a bare fiber optic. This innovation simplifies instrumentation for endoscopic and intravascular imaging applications.
Area of Science:
- Biomedical Optics
- Fiber Optic Technology
- Medical Imaging
Background:
- Miniaturization of endoscopic and intravascular imaging probes is crucial for minimally invasive procedures.
- Traditional optical coherence tomography (OCT) systems often require bulky and complex probe designs.
- Developing simplified, monolithic probes can enhance the feasibility of OCT in diverse clinical settings.
Purpose of the Study:
- To demonstrate and analyze an all-fiber-optic common-path OCT system with a novel side-viewing bare fiber probe.
- To investigate the theoretical effects of fiber tip angle on system performance, including reference reflection and sensitivity.
- To explore the integration of a microlens with the bare fiber probe for performance optimization.
Main Methods:
- Fabrication of a side-viewing probe by angle-cleaving a single-mode fiber tip (~49 degrees) to induce total internal reflection for side illumination.
- Implementation of a common-path OCT configuration utilizing the bare fiber probe.
- Theoretical analysis of the impact of the cleaved fiber angle on reference reflection and system sensitivity.
- Experimental evaluation of the probe's performance in arterial tissue, obtaining circumferential OCT scans.
- Integration and testing of the bare fiber probe with a microlens to optimize performance.
Main Results:
- Successful demonstration of an all-fiber-optic common-path OCT system with a side-viewing bare fiber probe.
- Circumferential OCT scans were acquired from arterial tissue using the miniaturized probe.
- Theoretical analysis provided insights into the relationship between fiber angle, reference reflection, and system sensitivity.
- Optimization studies involving a microlens indicated potential for enhanced probe performance.
Conclusions:
- The developed side-viewing bare fiber probe offers a highly miniaturized and simplified design for common-path OCT.
- This approach holds significant potential for simplifying instrumentation in endoscopic OCT and intravascular OCT applications.
- The study highlights the advantages of combining common-path OCT principles with extremely simplified probe designs for future medical imaging advancements.
More Related Videos
07:02Alignment of Visible-Light Optical Coherence Tomography Fibergrams with Confocal Images of the Same Mouse Retina
Published on: June 30, 2023
14:21Optical Frequency Domain Imaging of Ex vivo Pulmonary Resection Specimens: Obtaining One to One Image to Histopathology Correlation
Published on: January 22, 2013
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures II: Colonoscopy
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to: