Spectrally variable two-beam coupling nonlinear deconvolution

Bahareh Haji-Saeed1, Sandip K Sengupta, William D Goodhue

  • 1Electrical and Computer Engineering Department, University of Massachusetts, Lowell, Lowell, MA 01854, USA. bahareh.haji-saeed@hanscom.af.mil

Applied Optics
|December 7, 2007
PubMed

Related Concept Videos

Deconvolution01:20

Deconvolution

Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
2D NMR: Homonuclear Correlation Spectroscopy (COSY)01:06

2D NMR: Homonuclear Correlation Spectroscopy (COSY)

Homonuclear correlation spectroscopy, or COSY, is a 2-dimensional NMR technique that provides information about coupled protons. Typically, the geminal and vicinal coupling are observed. For example, consider the COSY spectrum of ethyl acetate, where its 1D proton NMR spectrum is plotted along the vertical and horizontal axes with their corresponding chemical shift scale. Three spots on the diagonal corresponding to the three peaks in the 1D proton spectrum are called diagonal peaks. The COSY...