Self-sterilization using silicone catheters coated with Ag and TiO2 nanocomposite thin film
Yanyan Yao1, Yoshihisa Ohko, Yuki Sekiguchi
1Department of Urology and Molecular Science, Graduate School of Medicine, Yokohama City University, 3-9 Fukuura, Yokohama 236-0004, Japan. yanyan01@yokohama-cu.ac.jp
Abstract:
Ag/titanium dioxide (TiO(2))-coated silicon catheters were easily fabricated with Ag nanoparticles deposition on both the inside wall and the outside wall of TiO(2)-coated catheters by TiO(2) photocatalysis. This is an application of the silicon catheters coated with TiO(2), which possess a self-sterilizing and self-cleaning property combining with UV light illumination (Ohko et al., J Biomed Mater Res: Appl Biomater 2001;58:97). Ag/TiO(2)-coated silicon catheters exhibited a strong bactericidal effect even in the dark. When the 2-5 x 10(5) of colony-forming units of Escherichia coli, Pseudomonas aeruginosa, or Staphylococcus aureus were respectively applied to the surface of the Ag/TiO(2) catheters, which were loaded with approximately 15 nmol cm(-2) of Ag, 99% effective sterilization occurred in a very short time: 20 min for E. coli, 60 min for P. aeruginosa, and 90 min for S. aureus. Additionally, the Ag/TiO(2)-coated catheters possessed a strong self-cleaning property. Using UV illumination, the photocatalytic decomposition rate of methylene blue dye representing the self-cleaning capability, on an Ag/TiO(2) catheter which was loaded with 2 nmol cm(-2) of Ag, was approximately 1.2 times higher (at maximum) than that on TiO(2) coating alone. Furthermore, the Ag nanoparticles can be pre-eminently and uniformly deposited onto the TiO(2) coating, and the amount of Ag was easily controllable from a few nanomoles per square centimeter to approximately 70 nmol cm(-2) by changing the UV illumination time for TiO(2) photocatalysis. This type of catheter shows a great promise in lowering the incidence of catheter-related bacterial infections.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...